REGULATORY COMPLIANCE
Regulatory compliance is at the core of fire protection engineering, ensuring that building systems are designed, installed, and maintained to meet stringent life safety standards. Our team specializes in delivering code-compliant fire protection solutions that align with national standards such as NFPA, the International Building Code (IBC), and local jurisdictional requirements—including the New York City Building Code and Fire Code.
FDNY Fire Safety Plans
Our Fire Safety Plans (FSPs) are developed in full compliance with NYC Fire Code Chapter 4, which establishes essential requirements for fire prevention and occupant safety across various building types. These comprehensive plans include detailed emergency action procedures, fire prevention measures, fire alarm system operations, means of egress, fire watch staffing, and occupant evacuation protocols. The Emergency Action Plan (EAP) component specifically outlines the steps building occupants and staff must take during fire or other emergency situations to ensure safe and orderly evacuation or sheltering. We customize each FSP to the building’s unique layout and occupancy, ensuring alignment with FDNY regulations and Rule 3 RCNY Chapter 4. Our team guides clients through FDNY review and approval to deliver clear, actionable plans that enhance life safety and regulatory compliance.
Sprinkler, Standpipe, and Smoke Control Systems
For sprinkler systems, we adhere to IBC Section 903, ensuring alignment with NFPA 13 for automatic systems based on occupancy types and building heights. Standpipe system design follows IBC Section 905, which mandates installation based on building stories and floor area, complying with NFPA 14 standards. Smoke control systems must meet IBC Section 909 and NFPA 92, addressing designs for large-volume spaces and ensuring safe evacuations.
FDNY Fire Protection Plans
In accordance with NYC Fire Code Chapter 4, our Fire Protection Plans (FPPs) offer an exhaustive depiction of a building’s fire protection systems and components. These plans include detailed layouts and specifications for fire alarms, automatic sprinkler and standpipe systems, fire pumps, smoke control, and egress features. Required for new construction and major renovations, FPPs are submitted to the NYC Department of Buildings and reviewed by the FDNY to ensure all systems meet code requirements. Our experienced engineers prepare and coordinate FPPs to facilitate smooth permitting, minimize review times, and ensure comprehensive life safety system integration.
Egress Planning and Fire Hazard Assessments
Egress planning follows IBC Chapter 10, covering means of egress, ensuring compliance with NFPA 101 and NFPA 5000 for safe evacuation routes. Additionally, our fire hazard assessments align with IBC Section 414, which outlines provisions for hazardous materials and fire-risk mitigation, following NFPA methodologies for effective risk management.
Fire Protection Compliance
Our fire protection engineering services integrate specific provisions of the International Building Code (IBC) alongside NFPA standards to ensure comprehensive compliance across all aspects of fire protection systems.